Consilex Barrier-A zoom
Consilex Barrier-A image 1
Consilex Barrier-A image 2
Consilex Barrier-A image 3

Consilex Barrier-A

Silicone water repellent in an aqueous emulsion, for chemical barriers

Solution of special modified silicone resins, dispersed in water, hydrophilic in the application phase, water-repellent and water-repellent after reaction with atmospheric carbon dioxide, for the preparation of water-repellent solutions for the creation of chemical barriers against capillary rising in masonry.
Components
Single-component
Appearance
Liquid
Customs code
3824 9970

Request product info

    By submitting I agree to the privacy notice

    Lines of belonging
    Linea prodotto Opus
    Sito tematico
    Opus Dry
    Where it is used
    How to use
    Technical data
    Additional content
    Warnings and precautions
    Media
    Related products
    Fields of application
    Formation, by injection, of horizontal chemical barriers for stopping capillary rising damp in building renovation and damp brickwork; water repellent and reinforcing treatment with slightly alkaline porous building materials: bricks, tiles, terracotta and crude ceramic materials, etc.
    Allowed supports
    Bricks
    Tuff
    Mixed walls (bricks and stones)
    Stone walls
    Preparation of supports
    Remove the existing plaster, only if necessary, up to at least one metre above the line of evident damp.

    Draw a line parallel to the outside kerb or inside flooring, at a distance of about 10-15 cm from the same. Prepare drilling points at 12 cm distance from one another on the traced line. The inclination of the holes should be about 20° down. The depth of the holes should be approximately 4/5 the thickness of the wall to inject. The drill bit to be used must have a diameter of 18-20 mm. Once the holes are finished, the dust produced by drilling is required to be eliminated.

    Mode of use
    The product can be diluted with demineralised water or with a hardness less than 35°F up to a maximum of 15-20% (it is recommended for use preferably without dilution). Proceed with the pure product or with the solution obtained, with low pressure injections by airless pump (manual or electric), directly into the designated holes in the masonry.
    Consumption may vary depending on the characteristics of the masonry and its thickness. By way of example, for 50 cm thick masonry, the indicative consumption of the aqueous solution is between 17 and 20 l/m.
    Consilex Barrier-A requires an adequate and as lengthy an exchange as possible with the atmosphere, for the hydrophilic-hydrophobic transformation: schedule an adequate waiting time prior to sealing the injection holes and coating the brickwork. It is advisable to create the chemical barrier with Consilex Barrier-A- when work commences at the construction site and to close the injection holes a few days before ends.
    Apply on porous media, with pH not exceeding 8.
    Protect glass and aluminium surfaces from contact with the product.

    Application methods
    Injection
    Low pressure airless nebulizer
    Tool cleaning
    Water
    Key features
    Density
    Density: 1.02 kg/dm³
    Nonflammable
    Nonflammable
    Shelf-life
    Shelf-life: 12 months
    Solvent-free
    Solvent-free
    Use wearing protective glasses
    Use wearing protective glasses
    Use wearing protective gloves
    Use wearing protective gloves
    Technical specifications
    Consumption
    From 3.5 to 4.0 litres of Consilex Barrier-A per linear metre of 10 cm thick masonry. Calculate the consumption in proportion to the thickness of the masonry to be restored.
    Available colors
    Transparent
    Packaging and dimensions
    Plastic can 10 l
    Plastic can 25 l
    Plastic can 5 l
    Storage and conservation
    Protect from freezing.
    Additional content

    Alternative uses of the product

    The product can also be used effectively as water repellent treatment of masonry surfaces in general. In this case, apply the product as it is on dry porous media. Protect the treated surfaces from rain in the hours immediately following application.

    Warnings
    The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
    Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.

    Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
    Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.

    The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.

    Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
    It is forbidden to dispose of the product and/or packaging in the environment.
    Photo gallery
    Technical Documentation

    Richiedi info sul prodotto

      By submitting I agree to the privacy notice

      Copyright © 2024 All Rights Reserved
      Powered by Webplease
      magnifiercross