Fibre-reinforced micro-concrete for the restoration of floors

Floor Tenax is a pourable, plastic/fluid, fibre-reinforced mortar for use in repairing deteriorated concrete flooring (with a reconstruction thickness from 4 mm to 20 mm) along with structural repairs of reinforced concrete cast in formwork. The formulation contains very fine yet high-strength cements, microsilica compounds with pozzolanic activity, rational granular aggregate composition curve (0.1–1.8 mm), special additives and a substantial amount of READYMESH fibre reinforcement. The product mixes with very low water/binder ratios (<0.32). The special formulation of Floor Tenax confers mechanical strength, fracture energy, exceptional durability and very high chemical-physical resistance to the repairs performed.
Components
Single-component
Appearance
Powder
Customs code
3824 5090

Request product info

    By submitting I agree to the privacy notice

    Obtained Certifications and Regulations
    EN 13813EN 1504-3C80 F10
    Lines of belonging
    Linea prodotto Floor
    Sito tematico
    Grout Power
    Features and benefits
    Where it is used
    How to use
    Technical data
    Additional content
    Warnings and precautions
    Media
    Related products

    Floor Tenax

    Floor Tenax has a workability time of approximately >120 minutes, after which the gripping process is triggered followed by a progressive hardening. The hygrometric shrinkage is extremely limited thanks to the presence of glass fibres and Readymesh PM 060 multi-filament polypropylene fibres, guaranteeing volumetric stability to restoration carried out. The performances that make Floor Tenax unique are:
    • very high mechanical compression strength (> 95 MPa at 28 days),
    • very high mechanical tensile and bending strength (> 14.5 MPa at 28 days),
    • excellent durability and resistance to chemical attacks.

    Fields of application
    Floor Tenax is used in the repair of deteriorated floorings with limited thickness (typical applications in the range 8 - 20 mm), characterised by high performance in terms of deformation, resistance and anti-cracking resistance and in particular where there is a need for rapid opening to traffic or rapid exercise after application. The main application fields are:
    • repair of industrial concrete floors with walkability allowed after approximately eight hours from casting and drive over allowed after 24-48 hours from application;
    • repair of joints in industrial flooring;
    • laying and fixing of manhole covers;
    • structural repairs and repairs generally performed with casting within formwork.

    Allowed supports
    Concrete
    Bricks
    Preparation of supports
    Application surfaces must be clean, free of dust, contamination, crumbling, inconsistencies, etc., and adequately saturated-surface-dry with water.
    Mode of use
    • The support must be prepared by mechanical scarification or hydro-scarification for a depth of not less than 8 mm. The scarification of the support is an absolutely necessary operation to ensure sufficient grip of the coating applied. In the case of localized patches or repairs, cut the contours at right angles with an angle grinder.
    • The support must not have traces of oils, greases, detergents.
    • The support must be in good condition, clean, course, without crumbling parts or dust (suction of all dust and debris with an adequately equipped vacuum system). Wash the surface with pressurized water. Saturate the support with water before applying and eliminate any excess water on the surface.
    • Application temperature: 5°C to 35°C.
    • We strongly recommend the use of a vertical axis mixer with planetary or double horizontal helical movement, for optimal performance of site operations.
    • MIXING: The powder is mixed with potable water in the measure of 11% - 12%, referred to the total weight of the mortar (about 2.75 lt per 25 kg bag) creating a homogeneous mixture. Mixing time: approximately 4 minutes with high-efficiency mixer.
    • In the case of large thicknesses (e.g.: manhole repairs) use compaction with a vibrating needle or tamp it down in a very intense way.
    • Level the surface with a vibrating screed on the prepared templates.
    • The surface must be protected after application by polyethylene sheets or anti-evaporation treatments. The latter should be sprayed on the freshly cast and restored surface (provide anti-evaporation treatments only if no other protective or aesthetic-protective applications are planned above: contact our technical service for advice on the most indicated surface protection methods and on the type of product that can be used as a curing compound).
    In the case of thicknesses exceeding 20 mm, Floor Tenax must be laid out, supported and floated on a suitable sub-base only with appropriate measures to ensure the structural adhesion and anchoring to the support itself. The methods of anchorage suggested include: laying with a special epoxy resin for structural construction joints (Syntech RGS or Syntech Pavisheer); or positioning a galvanized steel net with 5x5 cm mesh and 2 mm wire, which is spaced from the support plane of half the expected thickness of Floor Tenax and anchored to the same by "L"-shaped connectors fixed in holes resinated with Syntech Profix or fixed by nailing with "nail guns".
    Provide a cover with wet TNT and waterproof sheet as soon as the surfaces are walkable.

    Application methods
    Finishing trowel
    Pump
    Spatula
    Straight edge
    Tool cleaning
    Water
    Key features
    Max. recommended thickness
    Max. recommended thickness: 20 mm
    Min. recommended thickness
    Min. recommended thickness: 8 mm
    Mix with water
    Mix with water: 11 / 12.5 %
    Shelf-life
    Shelf-life: 12 months
    Temperature of use
    Temperature of use: +5 / +30 °C
    Technical specifications

    Compressive strength after 12 hours
    EN 12190

    8 N/mm²


    EN 12190

    > 45 N/mm²

    Compressive strength after 7 days
    EN 12190

    > 70 N/mm²

    Compressive strength after 28 days
    EN 12190

    > 90 N/mm²

    Flexural strength at 1 day
    UNI EN 196/1

    > 8 N/mm²

    Flexural strength after 7 days
    UNI EN 196/1

    > 11 N/mm²

    Flexural strength after 28 days
    UNI EN 196/1

    > 11 N/mm²

    Breaking load longitudinal

    4 MPa

    Taber abrasion resistance expressed as weight loss in grams (H22 wheel - 1000 g - 1000 rpm)
    ASTM D4060

    0.28 g

    Density
    UNI EN 1015-6

    2250 kg/m³

    Capillary absorption
    UNI EN 13057

    0.38 kg•h^0.5/m²

    Setting time

    3 h

    Bonding force
    UNI EN 1542

    > 2.5 N/mm²

    Static elastic modulus
    EN 13412

    35000 N/mm²

    Thermal conductivity

    0.73 W/mK

    Wear resistance
    UNI EN 13892-3

    0.8 cm³/50cm²
    Consumption
    Approximately 21 kg/m² of Floor Tenax for every centimetre of thickness to be implemented (approximately 2100 kg per cubic metre).
    Available colors
    Gray
    Packaging and dimensions
    Bag 25 kg
    Storage and conservation
    Store the product in its original packing, in a fresh and dry environment, avoiding frost and direct sunlight.
    Additional content

    Floor Tenax Family 

    characteristics and selection criteria

     

    Floor Tenax

    Floor Tenax Speedy

    workability

    castable mortar

    castable mortar

    fibers, maximum size

    6 mm

    6 mm

    Workability time

    approximately 120 minutes

    approximately 40 minutes

    Resistance to compression at 6 hours

    0

    8 MPa

    Resistance to compression at 12 hours

    8 MPa

    20 MPa

    Resistance to compression at 1 day

    >35 MPa

    >50 MPa

    Resistance to compression at 28 days

    > 95 MPa

    > 95 MPa

    Tensile strength

    4 MPa

    4 MPa

    Restoration of industrial flooring: selection criteria

    Thickness 10-20 mm

    Walkability at 12 hours approx.

    Light trucks at 24 hours approx.

    Drive over at 48 hours approx.

    Thickness 10-20 mm

    Walkability at 6 hours approx.

    Light trucks at 12 hours approx.

    Drive over at 24 hours approx.

     

    With a team of two men, finish areas of max 12-16 square meters at a time

     

    Restoration of industrial flooring: aesthetic performance

    possible inhomogeneity of colour and light halos

    possible inhomogeneity of colour and light halos

    Other fields of application

    Structural restorations in general with casting within formwork _ thicknesses from 15 to 30 mm

     

    Structural restorations in general with casting within formwork _ thicknesses from 15 to 30 mm

     

    Physical-mechanical values obtained at 20°C in laboratory conditions; workability and agility may vary depending on the temperatures present at the application

    Warnings
    It is always important to carry out preliminary tests to check the appropriateness of the product, depending on specific requirements. It is recommended to treat carefully the curing of the shotcrete for a few days, through continuous flushing of water or covering the same with a length of cloth made of polyethylene (winter period) or awning in non-woven fabric impregnated with water (spring/summer).The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
    Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.

    Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
    Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.

    The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.

    Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
    It is forbidden to dispose of the product and/or packaging in the environment.
    Photo gallery
    Video
    Technical Documentation

    Richiedi info sul prodotto

      By submitting I agree to the privacy notice

      Copyright © 2024 All Rights Reserved
      Powered by Webplease
      magnifiercross