Syntech HAG Acryl components are supplied ready to use.
Create 2 mixes in separate plastic buckets. Prepare only the quantity to be used each time.
Solution 1: Syntech HAG Acryl component A (25 kg resin) mixed with Syntech HAG Acryl component B (2.5 kg catalyst).
Solution 2: Syntech HAG Acryl component C (2 packs of 0.625 kg) mixed with clean tap water.
Attention:
The amount of water must be equal in volume to solution 1.
When mixing resin, always use a wooden or stainless steel spatula.
Determine the type and size of packers based on your pump and injection type. If reinforcing steel is present, try to locate it and plan the drilling pattern so that the reinforcement is not drilled. Drill holes at an angle of approximately 45° or less and in the direction of the crack. Make sure the hole goes through the crack.
The distance of the drilled holes depends on the width of the crack. Place the packer in the hole.
Prepare the pump to start the injection. The injection pressure varies depending on the structure and size of the crack. Start the injection at the lowest point of the crack. Continue injecting until resin flows out of adjacent packer(s). This is necessary to achieve uniform distribution of the material.
Stop pumping, unplug and move on to the next packer. Continue the procedure until the crack is completely filled.
After the material has cured, the packers can be removed. Holes drilled can be covered with Repar Tix Speedy HP quick-setting mortar. Clean and rinse the pump equipment with water whenever there is a stoppage longer than 15 minutes and, after completing the injection, rinse with a sufficient amount of water. Make sure the pump is clean and stop only when clean water comes out of the pump.
Reaction completed after
Viscosity
pH
Longitudinal elongation at break
Expansion capacity to 7 days
The consumption of the product depends on the size of the empty volume to be filled.
The material must be stored at temperatures between 5°C and 25°C to prevent the shelf life of the product from deteriorating over time. Keep away from heat and sunlight, in a dark and dry place.
The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.