SYNTECH PAVIDAMP

Three-component anti-humidity epoxy base, in aqueous emulsion

Code: SYN.0096

Components: 3

Appearance: Liquid + Powder

A three-component formulation, with a fluid epoxy resin base in aqueous emulsion (A + B) to be mixed with the third component (C) consisting of white cement and micro-quartz, specially designed to be used as a primer for cementitious surfaces in the presence of humidity and in conditions of hydraulic counter-thrust. Generally referred to as “wet-bonding”, it is particularly suitable as an anti-humidity barrier for the subsequent laying of parquet.

Linee di appartenenza

Certification obtained and Standards

Products and systems for the protection and repair of concrete structures - Surface protection systems for concrete

EN 1504-2

Products and systems for the protection and repair of concrete structures - Surface protection systems for concrete

General characteristics

pot-life

Pot-life: 60 min

density

Density: 1.60 (± 0.05) kg/l

use-wearing-protective-gloves

Use wearing protective gloves

min-recommended-thickness

Min. recommended thickness: 3 mm

shelf-life

Shelf-life: 12 months

uv-resistant

UV-resistant

temperature-of-use

Temperature of use: +10 / +35 °C

solvent-free

Solvent-free

Technical specifications

Resistance to carbonatation

> 500 m

Static elastic modulus

21 GPa

Hard to touch

35 - 45 min

Permeability to water vapor

Class I _

Mixing ratio of the components

1:1:3 _

Compressive strength

46 N/mm²

Concrete adhesion (cutting test)

> 2 N/mm²

Capillary absorption

0.02

Flexural strength

12 N/mm²

Complete hardening

8 - 10 h

Available colours

- White

Packaging and dimensions

- Kit: 1 Pail 2 kg [A] + 1 Pail 2 kg [B] + 1 Pail 6 kg [C]

- Pail 2 kg [A]

- Pail 2 kg [B]

- Pail 6 kg [C]

Consumption

From 0.50 to 0.60 kg of SYNTYECH PAVIDAMP for each square metre of surface to be covered.

Use fields

Building connection layers and smoothing cement surfaces; bottom layers for resinous coatings of floorings in the presence of damp subbases; anti-humidity barriers in concrete, brick and stone masonry; surfacings of porosity, cracks and superficial irregularities. As protection from rising damp for bases where operations with polyurea resins SYNTECH POLYUREA will be carried out.

Preparation of supports

The support on which the resin system is to be laid must be suitable for withstanding the stresses resulting from the intended use, such as static or dynamic loads, impacts, thermo-hygrometric dilatations, vibrations, etc. As regards the characteristics of the substrate (maximum humidity, cohesion, strength class, flatness, etc.) and the preparation of the surface that will accommodate the resin system, we recommend the requirements set out in chapter 5 of the UNI 10966 standard ("RESIN SYSTEMS FOR SURFACES HORIZONTAL AND VERTICAL - INSTRUCTIONS FOR DESIGN AND APPLICATION "). In any case, carefully clean and degrease the surfaces, removing any kind of dirt, paint residues or incoherent parts. Evaluate the most convenient type of mechanical preparation (shot peening, sandblasting, hydro-washing, etc.). The surfaces must also be free from discontinuity, and possibly leveled and regularized with products from the FLOOR line or the REPAR line. Apply by roller, brush or spray from 150 to 200 g / m2 of SYNTECH PRIMER EP-W to consolidate the substrate and facilitate the adhesion of the subsequent coating. Tiled floors, or floors covered with pre-existing resin, must be subjected to mechanical roughening carried out with shot blasting, milling, bush hammering, etc., until the total elimination of the waterproof crust and the opacification of the surfaces. Remove dust after abrasion.

Use method

Prepare the mixture of the 2 liquid components (A+B), pouring the contents of the component B in the container of the component A. Mix with drill for about 2 minutes. Add the pre-dosed hydraulic binder (high resistance white cement) to the mixture A+B, and mix with a mixer drill. To disperse the product optimally, pour the powders (component C) a little at a time, continuing to stir with drill, until a homogeneous lump-free mixture is obtained.

If it is used as a base: dilute with 10-15% by weight of clean, soft water and apply with a roller or brush. Indicative consumption: 0.4-0.5 kg/m² on regular supports, 0.7-0.9 kg/m² on irregular supports.

If it is used for fine finishing coats: load the system A+B+C diluted with 10-15% of fresh clean water, with 60-70% spheroidal quartz (0.04-0.25 mm). Apply with steel trowel or plastering trowel. Indicative consumption: 1-2 kg/m².

If it is used for medium finishing coats: load the system A+B+C diluted with 10-15% of fresh clean water, with 70-80% spheroidal quartz (0.1-0.5 mm). Apply with steel trowel or plastering trowel. Indicative consumption: 3-4 kg/m².

Application methods

- Brick trowel

- Brush

- Low pressure airless nebulizer

- Paint roller

Tool cleaning

- Thinner for resins

Permitted supports

- Concrete

- Floor screed

- Prefabricated concrete

Warnings, precautions and Ecology

Do not apply the product on wet bases.

Contact us now

Want to know more about our products?

Attention, correctly compile this field.
Attention, enter a valid email address.
Attention, correctly compile this field.

By submitting I accept the privacy policy

Attention, correctly compile this field.

Subscribe to the newsletter

Share

Products on display

  • Syntech H.A.G.
  • Sanawarme
  • Opus Dry